Eurocode

XFrame2d includes integrated Eurocode design checks for both steel and timber structures.

Steel Design - EN 1993-1-1

For steel beams, the following checks are performed:

  • Cross-section resistance (N, V, M)
  • Buckling resistance
  • Lateral-torsional buckling resistance
  • Combined bending and compression

Timber Design - EN 1995-1-1

For timber beams, the following checks are performed:

  • Bending stress
  • Shear stress
  • Compression/tension stress
  • Combined stress
  • Deflection limits

Analysis Method

XFrame2d uses geometric non-linear analysis (second-order analysis) for Eurocode checks. This approach:

  • Automatically includes P-delta effects
  • Accounts for initial imperfections
  • Allows buckling length equal to system length

See Buckling for more details on the calculation approach.

Unity Checks

Results are displayed as unity checks (UC):

  • UC < 1.0: Beam satisfies requirements OK
  • UC > 1.0: Beam does not satisfy requirements Warning

Double-click on the unity check indicator to see the detailed calculation.